OUTAGE POWER · FREE PLANNING TOOL

How long will your power station last?

When the power goes out, you may only need a few lights, your internet and a way to charge a laptop. Start with the things your family needs most. Add them below to see how long your battery might last, or what size to look for.

Quick answer: Battery capacity in watt-hours tells you how much energy is stored. Device watts tell you how fast you use it. Runtime is available energy divided by average watts. Check running and startup power separately before connecting anything.

New to watts and watt-hours? Start here ↓

BUILD YOUR PLAN

What do you want to keep running?

Use this tool for devices plugged into a power station’s regular AC outlets, like the outlets in your home. It estimates one charge, without solar or other charging. It does not include devices connected directly to USB or DC ports.

1 Your battery and time

Battery assumptions 85% allowance · full charge · 10% held back

Leaving 10% unused gives you a little room in your plan. You can change this. If your station stops supplying power at a set charge level, allow for that too.

2 What do you need to run?

Start with your essentials. Add devices that could run together, and enter the watts each one uses. Your entries stay in this browser.

Where do I find a device’s watts?

Look for input watts (W) on its label or in its manual. If you have a plug-in energy meter, measure the device while you use it normally. A label or charger rating may show a maximum rather than what it uses all the time.

Do not enter a charger’s USB output rating as its AC power draw. If you are unsure, leave that device out until you can check it. A device you leave out is not covered by the result. The sample plan shows the steps without guessing your appliance’s needs.

For a fridge, use the cycling help below. A single reading will not tell you how much energy it uses over a day.

My fridge switches on and off. What should I enter?

Enter its watts while running, choose “Cycles on and off,” then enter the share of time it runs. For example, 20 minutes out of each hour is about 33%. This is an average, not a promise about when the compressor runs.

A plug-in energy meter used over a full, representative day is better than one quick watt reading. If it records 1.2 kWh in 24 hours, average draw is 1,200 ÷ 24 = 50 W. With a 150 W running draw, that works out to about 33% on-time. Measure your own appliance; those numbers are examples.

Averaged runtime can be misleading for a short outage or a fridge cooling down from warm. The station still needs enough power for the full running and startup load.

3 Can the station power these devices? fill this in when you know the ratings

Copy these two ratings from the station manual. Continuous output is the power it can supply while devices run. Surge output is the brief extra power it can supply at startup. Leave a field blank if you do not know it.

A surge rating alone does not prove an appliance will start. Its duration, voltage, waveform and individual outlet limits matter too. Do not use a voltage-reducing “boost” mode as the normal output rating.

MAKE SENSE OF THE NUMBERS

Two checks before you buy or connect.

01

Enough energy for the time?

Watt-hours (Wh) measure stored energy. Watts (W) measure how fast devices use it. A 100 W load uses 100 Wh in one hour. Bigger Wh capacity usually means more time at the same load.

EIA explains watts, watt-hours and kilowatt-hours.

02

Enough power to run and start?

A station must support all running devices at once. A motor or compressor may also draw extra power when it starts. A big battery cannot make up for an undersized AC output.

Check your exact station and appliance manuals. This estimate does not approve a connection or guarantee uninterrupted power.

How this calculator works

For each device, we multiply watts × quantity × on-time fraction. We add those numbers to get the average load. For the running-power check, we use full running watts, even when a device cycles.

Available energy = battery Wh × usable charge fraction × energy allowance fraction

Estimated runtime = available Wh ÷ average W

Capacity needed = average W × hours ÷ usable charge fraction ÷ energy allowance fraction

For a full battery with 10% left unused, the usable charge fraction is 0.90. An 85% energy allowance is 0.85.

The default 85% allowance is a rough AC planning assumption. It is not a fixed efficiency rating. Jackery uses a 0.85 factor in its runtime guidance. You can change the allowance or enter measured delivered AC energy instead. We do not subtract conversion losses twice.

For example, 1,000 Wh × 90% of the charge available × 85% allowance = 765 Wh. At an average 85 W, the estimate is 9 hours. Eight hours at that load needs about 889 Wh of rated capacity under the same assumptions. These are example numbers, not results from equipment we tested.

Why actual runtime may be shorter

Cold or heat, battery age, changing loads, cutoff settings and inverter use can change the result. At a very low load, a simple percentage can miss a lot of the station’s own power use. Treat the result as a planning estimate and check actual operation before an outage.

EcoFlow explains runtime limits, low-load overhead and battery settings. Actual performance still depends on your station and devices.

Can I enter my battery in amp-hours instead?

Use the station’s rated Wh if available. For a battery rated in amp-hours, Wh = Ah × the battery’s nominal voltage. For example, 100 Ah × 12.8 V = 1,280 Wh. Do not use the 120 V AC outlet voltage for this conversion. A separate battery and inverter also need their own operating limits and loss data.

What if I only use a device for part of the outage?

This version assumes your entered average load continues throughout the plan. You can remove a device to compare an essentials-only plan. Do not use the cycling percentage to hide a large running or startup load. A detailed start-and-stop schedule needs a separate energy budget.

Does this include solar charging or a refrigerator food-safety time?

No. This is a one-charge estimate with no incoming energy. Solar varies with daylight and conditions. A runtime estimate is not a food-safety clock and cannot tell you whether refrigerated food stayed safe.

Keep the plan within the equipment’s instructions

Keep vents clear and follow the station’s temperature, moisture, cable and outlet limits. Do not connect a station to household wiring through a wall outlet. This tool does not size medical or life-sustaining backup, a UPS transfer system or an installed whole-home system.

Build the rest of your outage plan

Method checked October 31, 2026. The examples are calculations, not equipment tests. This calculator does not save your entries or send them to us. Reloading clears your plan. Site-wide advertising and privacy policies still apply.